How Much Home Lighting Do You Need? Another Approach

Modern Home Lighting

Craig DiLouie

One way to determine required light levels for a room is to use simplified lighting design calculations to determine the number of lumens required and, in turn, the number of lamps and luminaires needed to produce these lumens. There’s another approach, more like a rule of thumb in residential lighting design, that is worth mentioning.

The approach is based on wattage. What do watts, a measure of electrical loading and an element of cost, have to do with lighting a room? The simple answer is that most people are accustomed to buying incandescent lamps based on standard wattages such as 60W and 100W, and can assign them to an understood level of brightness.

The mindset is changing, however, because energy legislation is eliminating standard incandescent lamps in favour of more-efficient types that produce similar light output (lumens) for a lower wattage. So the primary metric is becoming lumens, not watts.
Nonetheless, performing a simplified lighting design based on watts remains possible. Here’s the rule of thumb formula: Take the area of the room (length x width) and multiply by 1.5 for general lighting and 2.5 for task lighting. The result is the minimum amount of wattage needed for lighting in the room. Accent lighting would be treated separately.

Therefore, if we have a 12 ft. x 14 ft. living room, we’d need (12 x 14) x 1.5W = 252W for general lighting and (12 x 14) x 2.5W = at least 420W budget for task (e.g., reading) lighting.
Other home lighting approaches

Another way of doing the task lighting is to restrict the space dimensions to the task area. So a kitchen island is 6 ft. x 4 ft., (6 x 4) x 2.5W = at least 60W dedicated to that area.

In the old days of standard incandescent wattages, we’d be considered done, but now we have energy-saving incandescent lamps, LED lamps and compact fluorescents, all of which produce light at varying wattages:

Lighting Watts Chart

There are several approaches to adjust wattage we could use. One is to select our lamp and adjust accordingly. If the room was going to feature 100W incandescent lamps, but will instead use 23W CFL, then 23W / 100W = 0.23. Therefore, in our living room example, where we needed a minimum of 252W for general lighting, we would instead need 252W x 0.23 = 58W.
Another approach is to pick the most popular incandescent wattage, which is 60W, and base everything on that as a standard to get a rough number. So if our living room needs a minimum of 252W for general lighting, we’d multiply that by a factor of say 0.72 for energy-saving incandescent (181W), say 0.13 for LED (33W) and say 0.25 for CFL (63W).

Things get messy for those odd applications where it makes sense to mix lamps in the same space. In that event, base it on lumens, using the intended incandescent lamp types or 60W as a standard. Our living room example requiring at least 252W for general lighting translates to 4.2 sixty-watt incandescent lamps, or 4.2 x 800 = a minimum budget of 3,360 lumens. That budget could then be divided among the different lamp types.

The end result is pretty simple and straightforward but is a rule of thumb. The more precise approach is to evaluate activities, determine appropriate light level, and choose lamps and luminaires that produce the required light output, taking into account coefficient of utilization and how the light is distributed. As an example of that last point, a luminaire with a reflective interior surface and omnidirectional lamp would emit a different light pattern and lumen output than the same luminaire fitted with a directional lamp.


Craig DiLouie, Principal of ZING Communications, Inc., is a lighting industry journalist, analyst and marketing consultant; cdilouie@zinginc.com. This article has been reprinted, with permission from IES, from Light Logic for the 21st Century: http://ieslightlogic.org

 

 

 

Related Articles


Changing Scene

  • Leviton Canada Appoints Nick Foster as Sales Director for Atlantic Region

    Leviton Canada is delighted to announce the well-deserved promotion of Nick Foster to the esteemed position of Sales Director for the Atlantic region, effective July 2nd, 2024. “Nick, a valued member of our team since 2015, has consistently demonstrated exceptional leadership acumen and a remarkable ability to foster strong client relationships,” said the company via LinkedIn. Read More…

  • Eureka Wins Red Dot Award for Atoll

    Eureka is pleased to announce that its Atoll luminaire has received a Red Dot Design Award for Product Design. It is the 10th consecutive year that Eureka products have been honored with this prestigious award, which is a testament to the company’s consistency and relentless drive to design the best luminaires in the market. Eureka has… Read More…


Design

  • Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    In September 2020, the picturesque city of New Westminster near Vancouver in British Columbia suffered a devastating setback when an intentionally set fire destroyed much of the city’s waterfront park, including its urban beach, sand volleyball courts, and iconic art installation known as Wow Westminster. The fire, which burned for ten days before firefighters could… Read More…

  • Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    May 30, 2024 A unique example of intimate spaces created using Lumentruss products at the Honeyrose Hotel. HONEYROSE Hotel, Montreal, a Tribute Portfolio Hotel. The beautifully inspired Art Deco boutique hotel located in the heart of Montreal is an exemplary demonstration of integrating layers of light into the architectural design to bring the architecture to… Read More…


New Products

  • FLL Series Perimeter Lighting from Stanpro

    FLL Series Perimeter Lighting from Stanpro

    The FLL Series is ideal for general lighting of grounds, storage yards, car dealerships, parking lots, as well as signage and building facade lighting. These high-power perimeter lights are designed for ease of installation with a snap-together feature that allows for easy optic interchangeability to accommodate different applications. Color temperature and wattage can be changed… Read More…

  • Dals 2-In-1 Low-Voltage Driver And Dimmer

    Dals 2-In-1 Low-Voltage Driver And Dimmer

    Replace your 12V driver with this 12V dimmer switch with an integrated driver to control the brightness of low voltage lights. Connect this unit to your 120V input current, and all your lights will dim to a nice, soft glow. Read More…