Exploring Unplanned Costs of LED Lighting Retrofits

November 3, 2017

Kevin Morin

There has been a lot of discussion around the office lately about the relationship between energy management and power management.

While sometimes used interchangeably, the distinction made between these two disciplines typically involves analysis of power distribution systems for energy cost saving (energy management) or for improvement of electrical reliability or availability (power management). Of interest to my colleagues are situations where these disciplines overlap or impact the other.

A commonly raised example is in the implementation of energy conservation measures that are expected to improve efficiency and lower energy costs but end up causing unplanned problems that negatively affect electrical network reliability. One example is with poorly conceived load shedding and power control solutions that degrade normally reliable utility power delivery. Another even more common example is in the introduction of “energy saving” non-linear loads that end up generating power quality issues within a facility. For example, power quality issues can be found with the introduction of variable frequency drives (VFD) that reduce the current draw of large electrical motors or with LED lighting systems that use a semi-conductor to convert incoming AC power to DC to produce light levels equivalent to traditional incandescent or florescent light while reducing kW consumption up to 75%.

While many of my past posts to this blog have focused on ways the Internet of Things (IoT) has impacted electrical power distribution and the Critical Power EcoXperts who are on the front line of this new frontier, developing unique opportunities that are IoT enabled, for this post I wanted to dig deeper into this relationship between managing energy cost, while maintaining strong energy quality (and therefore reliability). LED lighting is a great reference point for this, and so I’ve connected with a few colleagues to help explore the common power quality concerns raised by an LED lighting retrofit, and how the proliferation of LEDs in commercial buildings is changing the expectation of system integrators who work in those buildings.

Power quality impacts of LED lighting

Anytime I’ve met with a facility manager, engineer or anyone responsible for an electrical distribution network, and the topic of power quality comes up, it is important to pause and find out what power quality really means to them. Power quality (PQ) problems can be described by the impact or distortion on a voltage or current waveform (i.e., Sag/Swell) or by the impact on a process or a piece of equipment (i.e., downtime, flicker), but at the end of the day power quality is personal, and no two situations are the same. I consulted with Remi Bolduc, a PQ expert in Schneider Electric’s partner competency centre to help me better understand the case of LED lighting. Remi’s research suggests we should consider three PQ related topics when discussing LEDs:

  • inrush current and circuit breaker nuisance tripping.
  • harmonic distortion and transformer overheating.
  • voltage distortion and LED degradation.

Remi’s experience has shown that the adage above holds true: depending on the facility, and the person that we are talking to, the PQ issues above may or may not be an immediate concern. More often, it is common for electrical issues to become a concern only after the impact becomes apparent in the form of a PQ event that impacts the electrical network’s expected performance. For more information on these topics related to LED lighting, Remi suggests you look at a white paper he has authored that specifically reviews the power quality impact of LED lighting. An important consideration is suggested in the white paper, which is that while a single LED light may have a very marginal impact on a facility’s electrical distribution network, a whole system of LED lights, and in particular LED lighting loads that share a circuit, may have cumulative effects related to harmonic distortion that pose a significant stress on electrical assets (capital assets!) such as cabling and transformers.

Identifying LED generated power quality issues before they impact electrical network reliability

I work with the brightest system integration companies in the world that are involved in the development of power management systems. These Critical Power EcoXperts use connected devices and edge control software from our EcoStruxure Power domain of expertise to monitor PQ conditions, and leverage connected service to help alert facility managers about issues before they become problematic. Monitoring harmonics and evaluating harmonic compliance is nothing new to most of them, in an industrial or critical power environment. Something has changed though; we are now seeing facilities like shopping centres, commercial properties, and campuses where harmonics issues were never considered problematic before, and which are now looking at this as a real threat to power reliability. In these types of facilities, our EcoXperts, who are certified with a Building Management System (BMS) badge, are more likely involved with the facility managers on traditional HVAC control topics. To understand their perspective better, I connected with my colleague, Martin Feder, who is responsible for Schneider Electric’s BMS EcoXpert network, and has a huge amount of experience with EcoStruxure Building domain. In his view, identifying power quality issues caused by LED lighting and other sources is becoming a standard expectation from the BMS solution by customers today and hence the knowledge of the BMS EcoXpert must be able to identify how to connect, analyze and then work to develop a mitigation plan for any such disturbances.

As the building management system becomes the digital hub of the building, in effect the central core control system with connectivity to other building systems, such as access control, security and of course the power management system. The BMS system integrator needs to have a good understanding of these other systems to be able to ensure that their influence on the overall building performance is monitored and controlled in harmony with the building’s other systems and dynamics. BMS EcoXperts who want to help monitor for potential issues caused to an electrical power network by LED lighting can take training from Schneider Electric to gain another badge in the EcoXpert Program: Critical Power. Alternatively, they can partner up with a company that has this certification, and work together to provide their customer with a well-rounded solution. In the case of LED lighting, and mitigation of power quality concerns, including the elimination of harmonics, a Certified Critical Power EcoXpert will be able to specify an innovative active filtering solution using Schneider Electric’s Accusine product.

As you can see, the relationship between energy management and power management is unique, and there are real challenges to facilities that want to truly improve their performance. Energy efficiency and operation efficiency are both possible, and working with service providers that understand this relationship is a great place to start.


Kevin Morin is a Certified Energy Manager with a passion for innovative solutions to complex problems. Kevin has been part of Schneider Electric’s power management business for 12 years, working with utilities, universities, commercial properties, data centres and just about anyone else that has needed to improve their understanding of energy cost, electrical system reliability, or the performance of their energy assets. Kevin is today responsible for developing a global network of highly skilled system integrator companies that form the backbone of Schneider Electric’s Critical Power EcoXpert program.

This article was first published as a Schneider blog HERE

Related Articles


Changing Scene

  • CSC LED Announces the Appointment of Patrick Ndlovu as Branch Manager (AB)

    CSC LED is happy to announce that Patrick Ndlovu has joined their growing team as Branch Manager in Calgary, Alberta. With extensive experience as a journeyman electrician and a strong background in sales, Patrick brings together technical expertise and a deep understanding of market dynamics. His practical experience in the field, combined with his sales… Read More…

  • Maxlite Expands c-Max Network Partners Ecosystem With Casambi Technologies

    MaxLite is pleased to announce the recent expansion of its c-Max Network Partners ecosystem with the addition of Casambi Technologies, a provider of wireless lighting control systems. This strategic partnership further enhances MaxLite’s c-Max Lighting Controls platform, offering customers an even wider range of advanced wireless control options. The collaboration with Casambi strengthens MaxLite’s commitment… Read More…


Design

  • Project Story: Sainte-Thérèse High School Outdoor Lighting Upgrade

    Project Story: Sainte-Thérèse High School Outdoor Lighting Upgrade

    August 6, 2024 Built in 1980, the building that houses Sainte-Thérèse high school, in Quebec Canada, was looking a little worse for the wear. Renovation work began with two major projects: introducing a multidisciplinary sports centre, as well as redesigning the parking lots.  The employee and visitor parking lots were completely reconfigured during phase 1… Read More…

  • Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    In September 2020, the picturesque city of New Westminster near Vancouver in British Columbia suffered a devastating setback when an intentionally set fire destroyed much of the city’s waterfront park, including its urban beach, sand volleyball courts, and iconic art installation known as Wow Westminster. The fire, which burned for ten days before firefighters could… Read More…


New Products

  • SATCO|NUVO: SATCO-Escent Decorative Lamps

    SATCO|NUVO: SATCO-Escent Decorative Lamps

    Discover the elegance of “Satco-Escent” Satin Spun light bulbs, which combine the classic charm of incandescent lighting with the advantages of modern LED technology. The exquisite Satin Spun finish evokes the look of a vintage gas flame, while the unique shape of the bulb adds a touch of contemporary style. This family is available in… Read More…

  • SATCO|NUVO: LED HID Replacement Lamps

    SATCO|NUVO: LED HID Replacement Lamps

    Easily upgrade dated HID lamps with energy saving LED bulbs. SATCO’s long lasting HID replacement lamps offer outstanding efficacy in applications where low-maintenance is the goal: streetlights, warehouses, retail, gymnasiums and more. With a variety of lamp shapes and bases available in clear filament or white finish, in color temperatures from warm white to natural… Read More…