The retrofit and relight business is in full swing today. A variety of new LED replacement luminaires, retrofit/conversion kits and lamps are available from a variety of manufacturers, and whether we are talking about a T12 to T8 fluorescent conversion or fluorescent to LED, the economic value proposition and project mechanics are well understood.

The most straightforward applications for retrofit kits typically involve replacing antiquated technology with a more efficient lighting solution which reduces the operational costs (energy & maintenance), maintains or improves visual performance and where the initial cost can be justified through a reasonable payback time period. However, in recent years the high-impact financial nature of some lighting retrofits has necessitated a greater level of front-end coordination with customer operations and accounting personnel. This is especially true when it comes to understanding the dynamics involving repurposing, replacing or modifying fixed assets such as lighting equipment, which for many facilities has been amortized over several decades. As a result, outright replacing luminaires early into predetermined useful life may leave a large balance to be written off as a loss.

Commercial buildings are typically depreciated over 39 years. As a result, fixed lighting systems are frequently depreciated along with the building. Leasehold improvements on the other hand are handled a bit differently and are commonly depreciated over the life of the lease or over the useful life of the asset, whichever is less (e.g., 15 years instead of 39 years). This is because you typically only have to undo and redo leasehold improvements every time a tenant moves out.

Depreciation can optionally be accelerated through segregation. This allows you to divide the building into all of its constituent systems, some of which have a life that is much shorter than 39 years. For instance, if your building has a lighting system with a design-life of 15 years, you could write it off over a 15-year period. While this moves a lot of your depreciation forward and saves you money in the beginning, you have less depreciation to claim in the future.

When it comes time to write off an existing lighting system, this process involves removing all traces of the fixed asset from the balance sheet, so that the related fixed asset account and accumulated depreciation account are reduced.

There are two scenarios under which you may write off an existing lighting system (fixed asset). The first situation, which we will cover here, arises when you are eliminating/removing a fixed asset without receiving any payment in return (e.g., accepting resale or recycling value). This is a common situation where existing lighting systems are being scrapped when they are obsolete or no longer in use and there is no resale market for them. In this case, the owner must reverse any accumulated depreciation and the original asset cost. If the asset is fully depreciated, this is the extent of the process. The second situation, which will not be covered here, arises when the customer sells an asset that is or has been depreciated.

Using the above example, the Best Customer Corporation (BCC) purchases and installs a $150,000 lighting system and recognizes $10,000 of depreciation per year over the following 15 years. At that time, the lighting system is not only fully depreciated, but also ready for the scrap heap. BCC disposes of the lighting system, and records the following entry.

Retrofit Chart 1

A variation on this first situation is to write off a lighting system (fixed asset) that has not yet been completely depreciated. In this situation, write off the remaining undepreciated amount of the asset to a loss account. To use the same example, BCC disposes of the system after 10 years, when it has not yet depreciated $50,000 of the asset’s original $150,000 cost. In this case, BCC records the following entry.

Chart 2

Based on the dynamics at play for the customer, it may be more financially reasonable to upgrade a lighting system and avoid the write-off. This may be especially true in situations where the lighting system is being depreciated along with the building life and a decision to upgrade the lighting occurs early into this timeframe. The generally accepted accounting principles (GAAP) indicate that if a portion of the original asset is being replaced (e.g., lamps, ballast, sockets, reflector, etc.), then theoretically the carrying value of these components should be removed from the accounting records and recorded as a loss in the period of the replacement. This accounting is seldom used in practice because, in general, accounting records for fixed assets are not maintained in the painstaking detail necessary to determine the carrying value of the individual components that comprise each asset. Instead, most companies will capitalize the replacement components (e.g., lighting retrofit kit) under the rationale that the portion of the asset besting replace would have been depreciated sufficiently based on the useful life of the “host asset” so that at the time of replacement, little or no carrying value would remain to be removed.

In summary, lighting professionals and customers must carefully consider the financial variables involved in lighting retrofit and relight projects. These must, at a minimum, be evaluated on a customer-by-customer, and in many cases, building-by-building basis. Where a write-off is not ideal, a strong case can be made for retrofitting versus replacing lighting systems. It is also important to note that there may be other reasons to retrofit versus replace luminaires. These reasons may include, but are certainly not limited to, the impact to productivity through disruption, air quality (from disturbing insulation materials or dust) and of course the initial system cost. Some examples of ideal retrofit product candidates where any or all of the concerns mentioned above are involved would include Kim Lighting’s HID to LED upgrade kits, Beacon Products’ LRK series, Prescolite’s Retroficient Series, and Columbia’s upcoming GORK and SLK.


Chris Bailey is the Director of Business Development and Product Innovation for Hubbell Lighting and is responsible for Hubbell Lighting’s Lighting Solutions Center. He is NCQLP Lighting Certified (LC), a LEED-Accredited Professional for Building Design & Construction as granted by the U.S. Green Building Council, DDI certified professional facilitator and a member of the Illuminating Engineering Society (MIES). This article first appears at a Hubbell Lighting blog: http://www.hubbelllighting.com/company/illuminations/money-matters-retrofit-or-relight.

Related Articles


Changing Scene

  • Leviton Achieves 29% Decrease in Overall GHG Emissions from 2021 to 2023

    Leviton recently announced that it achieved a 29% drop in overall greenhouse gas (GHG) emissions from the 2021 baseline year, a major step towards the goal of becoming carbon neutral company-wide by the year 2030 with their CN2030 program. Through on-site renewable energy generation, accelerated energy efficiency efforts, moving to renewable and clean energy providers,… Read More…

  • LEDVANCE Canada Welcomes Gary Repko as Sr. Sales Representative in Central Region

    Recently, LEDVANCE Canada was delighted to welcome Gary Repko as its Sr. Sales Representative for the central region of Canada. Linda Conejo, a Regional Sales Manager for LEDVANCE Canada, stated, “Gary has 12+ years industry experience and brings a wealth of knowledge having worked with engineers, contractors and distributors. We are excited that he has… Read More…


Design

  • Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    In September 2020, the picturesque city of New Westminster near Vancouver in British Columbia suffered a devastating setback when an intentionally set fire destroyed much of the city’s waterfront park, including its urban beach, sand volleyball courts, and iconic art installation known as Wow Westminster. The fire, which burned for ten days before firefighters could… Read More…

  • Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    May 30, 2024 A unique example of intimate spaces created using Lumentruss products at the Honeyrose Hotel. HONEYROSE Hotel, Montreal, a Tribute Portfolio Hotel. The beautifully inspired Art Deco boutique hotel located in the heart of Montreal is an exemplary demonstration of integrating layers of light into the architectural design to bring the architecture to… Read More…


New Products

  • WaveLinx LITE Node from Cooper Lighting Solutions

    WaveLinx LITE Node from Cooper Lighting Solutions

    The WaveLinx LITE Node (OEM-WLN) is a wireless to 0-10V control module designed to be integrated into the luminaire. The LITE Node offers two continuous 0-10V output channels that can be used to control dim-to-off 0-10V LED drivers with auxiliary power. The device has a built-in 802.15.1 radio (Bluetooth) that is used to communicate with other WaveLinx… Read More…

  • Peerless Electric: Peerlux Series ECR-G Luminaire

    Peerless Electric: Peerlux Series ECR-G Luminaire

    Introducing Peerless Electric’s ECR-G luminaire, part of the Peerlux Series, a germicidal luminaire for suspended mounting with aircraft cables. Designed to help clean the air of bacteria, fungi, their spores and inactivating viruses by destroying their ability to replicate. A stylish linear fixture that provides indirect UVc disinfection. Read More…