How Much Home Lighting Do You Need? Another Approach

Modern Home Lighting

Craig DiLouie

One way to determine required light levels for a room is to use simplified lighting design calculations to determine the number of lumens required and, in turn, the number of lamps and luminaires needed to produce these lumens. There’s another approach, more like a rule of thumb in residential lighting design, that is worth mentioning.

The approach is based on wattage. What do watts, a measure of electrical loading and an element of cost, have to do with lighting a room? The simple answer is that most people are accustomed to buying incandescent lamps based on standard wattages such as 60W and 100W, and can assign them to an understood level of brightness.

The mindset is changing, however, because energy legislation is eliminating standard incandescent lamps in favour of more-efficient types that produce similar light output (lumens) for a lower wattage. So the primary metric is becoming lumens, not watts.
Nonetheless, performing a simplified lighting design based on watts remains possible. Here’s the rule of thumb formula: Take the area of the room (length x width) and multiply by 1.5 for general lighting and 2.5 for task lighting. The result is the minimum amount of wattage needed for lighting in the room. Accent lighting would be treated separately.

Therefore, if we have a 12 ft. x 14 ft. living room, we’d need (12 x 14) x 1.5W = 252W for general lighting and (12 x 14) x 2.5W = at least 420W budget for task (e.g., reading) lighting.
Other home lighting approaches

Another way of doing the task lighting is to restrict the space dimensions to the task area. So a kitchen island is 6 ft. x 4 ft., (6 x 4) x 2.5W = at least 60W dedicated to that area.

In the old days of standard incandescent wattages, we’d be considered done, but now we have energy-saving incandescent lamps, LED lamps and compact fluorescents, all of which produce light at varying wattages:

Lighting Watts Chart

There are several approaches to adjust wattage we could use. One is to select our lamp and adjust accordingly. If the room was going to feature 100W incandescent lamps, but will instead use 23W CFL, then 23W / 100W = 0.23. Therefore, in our living room example, where we needed a minimum of 252W for general lighting, we would instead need 252W x 0.23 = 58W.
Another approach is to pick the most popular incandescent wattage, which is 60W, and base everything on that as a standard to get a rough number. So if our living room needs a minimum of 252W for general lighting, we’d multiply that by a factor of say 0.72 for energy-saving incandescent (181W), say 0.13 for LED (33W) and say 0.25 for CFL (63W).

Things get messy for those odd applications where it makes sense to mix lamps in the same space. In that event, base it on lumens, using the intended incandescent lamp types or 60W as a standard. Our living room example requiring at least 252W for general lighting translates to 4.2 sixty-watt incandescent lamps, or 4.2 x 800 = a minimum budget of 3,360 lumens. That budget could then be divided among the different lamp types.

The end result is pretty simple and straightforward but is a rule of thumb. The more precise approach is to evaluate activities, determine appropriate light level, and choose lamps and luminaires that produce the required light output, taking into account coefficient of utilization and how the light is distributed. As an example of that last point, a luminaire with a reflective interior surface and omnidirectional lamp would emit a different light pattern and lumen output than the same luminaire fitted with a directional lamp.


Craig DiLouie, Principal of ZING Communications, Inc., is a lighting industry journalist, analyst and marketing consultant; cdilouie@zinginc.com. This article has been reprinted, with permission from IES, from Light Logic for the 21st Century: http://ieslightlogic.org

 

 

 

Related Articles


Changing Scene

  • RENO Lighting Announces New Vice President of Sales

    RENO Lighting Announces New Vice President of Sales

    It is with great excitement that RENO Lighting introduces Jean-Claude Lespérance as Vice President of Sales at RENO Lighting. With over 35 years of experience in the Canadian electrical industry, Jean-Claude brings extensive knowledge of the market and strong relationships with key industry stakeholders, suppliers, and customers. Holding a college diploma in Electrodynamics and a… Read More…

  • Contact Delage Announces New Partnership with Zilux

    Contact Delage: New Representation Agreement – Zilux

    Contact Delage is pleased to announce a new partnership with Zilux for the representation of their products in the regions of Montreal, Laval, Estrie, Lanaudière, Laurentides, and Montérégie. Specializing in the design of aluminum lighting and urban furniture, Zilux, a Quebec-based manufacturer, combines innovation and durability to enhance your outdoor design projects. Their expertise in… Read More…


Design

  • Artika: Spring Kitchen Lighting Tips

    Artika: Spring Kitchen Lighting Tips

    After a long winter, spring is finally here to make our world feel bright and full of life, and some well-thought-out tweaks to your kitchen lighting can do the same for your home! These relatively simple changes can not only make your kitchen more functional but can also bring together the overall look and feel… Read More…

  • Light ARchitect Is Revolutionizing Lighting Design for Architects & Designers

    Light ARchitect Is Revolutionizing Lighting Design for Architects & Designers

    Traditionally, lighting design could be a tedious process, often involving physical mockups, time-consuming calculations, and static renderings using multiple software tools. With advancing technology, these traditional methods are giving way to more sophisticated tools that enhance precision, speed, and visualization. On the downside, many of the new tools are not particularly intuitive and the learning… Read More…


New Products

  • Intermatic: ALC4-R 4-Channel 0-10 V Lighting Controller

    Intermatic: ALC4-R 4-Channel 0-10 V Lighting Controller

    The ALC4-R lighting controller is a four-channel 0-10 V dimming controller designed to work with ARISTA Lighting Control System by Intermatic. These units can work with either 0-10 V or 1-10 V lighting fixtures, including LED’s. Once installed, the ALC4-R unit(s) can be configured to work off of either scheduling, sensing, or a combination of… Read More…

  • Amico: Lunar Night Light – Behavioral Series

    Amico: Lunar Night Light – Behavioral Series

    Behavioral Health Lunar Series Night Lights bring a soft, low-level illumination to the patient room allowing clinical staff and patients to navigate safely in the dark, evening hours. The unique faceplate has minimal protrusion from the wall and provides even light distribution for optimal sight. For ultimate convenience, the Lunar Night Light is available with… Read More…