DLC Releases Technical Requirements V4.2

DLC Releases Technical Requirements V4.2

May 10, 2017

The DesignLights Consortium has released Technical Requirements V4.2, which includes new expansions and revisions to the technical requirements for solid-state lighting (SSL) products.

Technical Requirements V4.2 is the finalization of several months of discussions with DLC members and stakeholders, and includes the following expansions and revisions: new testing requirements for products under specialty use designations with the word “hazardous” in the designation descriptor; a revision to the linear replacement lamp policy to create new, distinct general applications for T5 and T5HO four-foot replacement lamps; and allowances to the efficacy requirements for products that have low CCT or high CRI.

New testing and reporting requirements for hazardous location lighting

Under the V4.2 requirements, products applying to a specialty use designation with a “hazardous” descriptor must undergo testing and certification to UL 844 by a relevant safety organization.

Linear replacement lamps

Four-foot linear replacement lamps are broken into three general application designations, with distinct eligibility, testing, and performance requirements:

  • T8 replacement lamps — LED lamps that are 48 inches long and employ a G13 base
  • T5 replacement lamps — LED lamps that are 46 inches long, employ a G5 base, and are intended to replace T5 fluorescent lamps
  • T5HO replacement lamps — LED lamps that are 46 inches long, employ a G5 base, and are intended to replace T5HO lamps

Allowances

The concept of allowances was first introduced with the release of Technical Requirements V4.0. Following review and deliberation of submissions received from manufacturers in response to a request for proposals on allowances needs, the DLC is launching an allowances program with allowances of up to 5% to the efficacy requirement for products that have low CCT or high CRI. Please note: V4.2 Allowances for CCT and CRI will be retroactively applied to all products on the QPL prior to 4/1/2017 (that is prior to the V4.0 de-listing).

Correction to multiple LED policy

Technical Requirements V4.2 includes a correction to the multiple LED policy, which previously was restricted to products employing multiple white-light LEDs only. This restriction is now removed.

Implementation timeline

The implementation timeline of Technical Requirements V4.2 affects only manufacturers of linear replacement lamps and hazardous location luminaires listed under specialty use designations that are affected by this revision:

  • manufacturers may submit applications that comply with these policy changes immediately
  • a submission grace period is in effect until May 19, 2017. During this grace period, manufacturers may submit listings to the DLC QPL under the V4.1 requirements
  • a listing grace period is in effect until July 28. Following this grace period, all products must meet the V4.2 requirements to remain listed

Find out more: www.designlights.org/news-events/news/dlc-releases-technical-requirements-v4-2/.

Related Articles


Changing Scene

  • Leviton Achieves 29% Decrease in Overall GHG Emissions from 2021 to 2023

    Leviton recently announced that it achieved a 29% drop in overall greenhouse gas (GHG) emissions from the 2021 baseline year, a major step towards the goal of becoming carbon neutral company-wide by the year 2030 with their CN2030 program. Through on-site renewable energy generation, accelerated energy efficiency efforts, moving to renewable and clean energy providers,… Read More…

  • LEDVANCE Canada Welcomes Gary Repko as Sr. Sales Representative in Central Region

    Recently, LEDVANCE Canada was delighted to welcome Gary Repko as its Sr. Sales Representative for the central region of Canada. Linda Conejo, a Regional Sales Manager for LEDVANCE Canada, stated, “Gary has 12+ years industry experience and brings a wealth of knowledge having worked with engineers, contractors and distributors. We are excited that he has… Read More…


Design

  • Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    Resilience Illuminated: Reviving Westminster Pier Park After Devastating Fire

    In September 2020, the picturesque city of New Westminster near Vancouver in British Columbia suffered a devastating setback when an intentionally set fire destroyed much of the city’s waterfront park, including its urban beach, sand volleyball courts, and iconic art installation known as Wow Westminster. The fire, which burned for ten days before firefighters could… Read More…

  • Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    Lumentruss Case Study: The Honeyrose Hotel’s Beautiful Redesign

    May 30, 2024 A unique example of intimate spaces created using Lumentruss products at the Honeyrose Hotel. HONEYROSE Hotel, Montreal, a Tribute Portfolio Hotel. The beautifully inspired Art Deco boutique hotel located in the heart of Montreal is an exemplary demonstration of integrating layers of light into the architectural design to bring the architecture to… Read More…


New Products

  • WaveLinx LITE Node from Cooper Lighting Solutions

    WaveLinx LITE Node from Cooper Lighting Solutions

    The WaveLinx LITE Node (OEM-WLN) is a wireless to 0-10V control module designed to be integrated into the luminaire. The LITE Node offers two continuous 0-10V output channels that can be used to control dim-to-off 0-10V LED drivers with auxiliary power. The device has a built-in 802.15.1 radio (Bluetooth) that is used to communicate with other WaveLinx… Read More…

  • Peerless Electric: Peerlux Series ECR-G Luminaire

    Peerless Electric: Peerlux Series ECR-G Luminaire

    Introducing Peerless Electric’s ECR-G luminaire, part of the Peerlux Series, a germicidal luminaire for suspended mounting with aircraft cables. Designed to help clean the air of bacteria, fungi, their spores and inactivating viruses by destroying their ability to replicate. A stylish linear fixture that provides indirect UVc disinfection. Read More…